Introduction
Heart rate and pulse are used as synonyms in everyday speech, and in most healthy people the two numbers match. However, they are not the same measurement, and the difference becomes important when a patient’s heart rhythm is abnormal. Medical writers and editors need to understand which measurement the source actually reports. This post defines both terms, shows how they are measured, explains when they diverge, and ends with tips for accurate documentation.
Defining the terms
Heart rate is the number of times the heart contracts per minute, specifically the number of ventricular contractions. It can be recorded directly from the heart by an ECG or by listening over the apex with a stethoscope.
Pulse is the pressure wave generated by each contraction as it travels along the arterial wall. It is felt at the body’s periphery, for example at the wrist, neck, or groin. Pulse rate is the number of these waves counted per minute.
In short, heart rate counts what the heart does, while pulse counts what reaches the artery. When every contraction ejects enough blood to produce a detectable wave, the two numbers are equal. When it does not, they differ.
How each one is measured
The method often tells you which term a document should use.
| Category | Heart rate | Pulse rate |
| What is counted | Ventricular contractions | Pressure waves in an artery |
| Manual method | Auscultation at the cardiac apex | Palpation at the radial, carotid, brachial, femoral or pedal pulse |
| Device method | ECG or cardiac monitor | Pulse oximeter or wearable using photoplethysmography |
| Usual abbreviation | HR | PR |
| Normal resting adult range | 60 to 100 beats per minute | 60 to 100 beats per minute |
Did you know that many consumer wearables label their optical reading “heart rate”, although the sensor actually detects the pulse wave at the skin?
When heart rate and pulse differ
The gap between the two is called the pulse deficit (or apical-radial deficit): the apical heart rate minus the radial pulse rate. It appears when some contractions are too weak to send a detectable wave to the wrist.
Common causes include:
- – Atrial fibrillation, where irregular filling means some beats eject very little blood.
- – Premature ventricular or atrial beats, which come early and may not generate a palpable pulse.
- – Other tachyarrhythmias with a short filling time.
For example, a patient in atrial fibrillation may have an apical heart rate of 140 while the radial pulse counts only 100.
Why the distinction matters in medical texts
- – Here are a few context examples where the distinctions between heart rate and pulse matter:
- – Clinical decisions: Rate-control targets in arrhythmia are based on the ventricular rate, not pulse.
- – Data source: A value from a pulse oximeter is a pulse rate, and one from an ECG monitor is a heart rate.
- – Additional data: A pulse note usually also covers rhythm (regular or irregular), volume, and symmetry between sides. Heart rate on its own says nothing about these.
- – Patient instructions: Leaflets that tell patients to “check your heart rate” at home usually mean taking the pulse at the wrist or with the help of the blood pressure monitor.
For medical translators, it is important to understand the method or source of the measurement to select the correct equivalent in your language. For medical writers, the safest habit is to keep the source’s term and its measurement method together, so that the record shows not only the number but what was actually measured.
This post was written for mymedpharm.info by Dr. Ridhi Sharma.
Dr. Ridhi Sharma is an MBBS graduate and medical writer with a clinical background and a keen interest in healthcare communication. She enjoys simplifying complex medical concepts and terminology into clear, accurate, and accessible content for diverse audiences.